Can’t Find What You Are Looking For? Find Out About Our Bespoke Design Solutions.

Read More.

  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701
  • Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701

Inherent Flame Retardant Linen Coated Blackout Fabric 100% Polyester for Curtains, NFPA 701

SKU: BG-FMTC-01

Fire Retardant Blackout Anti-UV Soundproof
NFPA701, NF-P92-503-M1, BS5815, DIN 4102-1
300cm
430gsm
100% Polyester
Flame Retardant
Curtain
Usually we provide A4 size samples, samples are free, you only need to pay the shipping cost, if you need more sample quantity, please contact us.

Test Report Summary: DIN 4102-1 Fire Behaviour Test for Building Materials

  • Exposed surface: White
  • Sample Description: Flame Retardant Coat Fabric
  • Color: Gray
  • Composition: Polyester
  • Test Requested: DIN 4102-1:1998 – Fire Behaviour of Building Materials and Elements, Class B1
  • Conclusion: The tested sample meets the Class B1 requirements of DIN 4102-1:1998.

Test Details

  • Sample Description: Flame Retardant Coat Fabric (Gray)
  • Area Density: 410 g/m²
  • Sample Size: 190mm x 1000mm & 190mm x 90mm
  • Conditioning: Samples were conditioned for at least 14 days at 23 ± 2°C and 50 ± 5% relative humidity.

Test Results

1. Brandschacht Test (DIN 4102-15 & 16)

  • Max. Flame Height: 40 cm
  • Melting/Burning Through: Yes (Lengthwise and Widthwise)
  • Burning Droplets: Yes
  • Average Residual Length: 62.3 cm (Lengthwise), 65.5 cm (Widthwise)
  • Max. Smoke Temperature: 154.7°C (Lengthwise), 151.8°C (Widthwise)

2. Ignitability Test (DIN 4102-1 Clause 6.2.5)

  • Fire Application Time: 15 seconds
  • Flaming Extinguished Before Gauge Mark: Yes (All specimens)
  • Flaming Reached Measuring Mark (within 20 seconds): No (All specimens)
  • Max. Flame Height: 7-9 cm
  • Molten Dripping: No
  • Smoke Development: Slight

Observations

  • Residual Length (After Brandschacht Test): Greater than 45 cm for all specimens, meeting Class B1 requirements.
  • Photo Appendix: SGS authenticated the photo on the original report.