  • Inherent Flame Retardant Mesh Fabric Fire Retardant Polyester for Upholstery
  • Inherent Flame Retardant Mesh Fabric Fire Retardant Polyester for Upholstery
  • Inherent Flame Retardant Mesh Fabric Fire Retardant Polyester for Upholstery
  • Inherent Flame Retardant Mesh Fabric Fire Retardant Polyester for Upholstery
  • Inherent Flame Retardant Mesh Fabric Fire Retardant Polyester for Upholstery

Inherent Flame Retardant Mesh Fabric Fire Retardant Polyester for Upholstery

SKU: BG-WGB-602

Fire Retardant
NFPA701
150cm
120gsm
flame retardant
100% polyester
Usually we provide A4 size samples, samples are free, you only need to pay the shipping cost, if you need more sample quantity, please contact us.

Test Report: NFPA 701:2019

Sample Information:

  • Sample Description: Inherent Flame Retardant Polyester Mesh Fabric
  • Color: White
  • Composition: Polyester
  • Sample Size: 400 mm × 150 mm
  • Fabric Weight: 116 g/m²
  • Configuration: Single Layer
  • Exposed Surface: Any surface
  • Sample Receiving Date: September 22, 2021
  • Test Performing Date: September 22, 2021 to September 29, 2021

Test Requested:

  • Standard: NFPA 701:2019 – Standard Methods of Fire Tests for Flame Propagation of Textiles and Films, Test Method 1.
  • Objective: To assess the flame propagation of the fabric sample under the conditions specified in NFPA 701:2019.

Test Details:

Specimen No. Mass Before Test (g) Mass After Test (g) Mass Loss (%) After-Flame Time (s) Burning Time on Floor (s)
1 7.51 5.25 30.09 0 0
2 7.43 5.52 25.71 0 0
3 7.32 5.21 28.83 0 0
4 7.33 5.27 28.10 0 0
5 7.24 5.37 25.83 0 0
6 7.45 5.60 24.83 0 0
7 7.38 5.25 28.86 0 0
8 7.55 5.31 29.67 0 0
9 7.30 5.28 27.67 0 0
10 7.47 5.22 30.12 0 0
Average 7.40 5.33 27.97 0 0

 


Observations:

  • Vigorousness of Burning: No
  • Molten Dripping: Yes
  • Odor of Smoke: Yes

Conclusion:

  • The tested sample meets the requirements of NFPA 701:2019, Test Method 1.
  • Performance Criteria (Chapter 10):

Fragments or residues falling to the floor shall not continue to burn for more than an average of 2 seconds.

The average weight loss of the specimens shall be 40% or less.

No individual specimen’s mass loss should deviate by more than 3 standard deviations from the mean.

If a retest is required, the second set of specimens must conform to these conditions.