Can’t Find What You Are Looking For? Find Out About Our Bespoke Design Solutions.
Linen Coated Blackout Fabric Fire Retardant Fabric for Curtains, Soft Drape, 100% Polyester, NFPA 701 Compliant
SKU: BG-FMTC-08
- NFPA701, NF-P92-503-M1, BS5815
- 300cm
- 430gsm
- 100% Polyester
- Flame Retardant
Test Report for Flame Retardant Coated Fabric According to DIN4102-B1 Standard
- Report Number: AJFS2209007335FF
- Sample Description: Flame retardant coated fabric, color gray, composition polyester.
- Test Requirements: According to DIN 4102-1:1998-05 standard, the fire behavior of building materials and elements is classified, testing for Class B1 materials.
- Test Results: The sample meets the requirements of Class B1 materials as per DIN 4102-1:1998-05 standard.
- Test Details:
- Brandschacht Test:
Exposed Surface: White surface
Maximum Flame Height: 40 cm (lengthwise), 40 cm (widthwise)
Flame Persistence Time: 00:38 (lengthwise), 00:44 (widthwise)
Melting/Burning Through: Yes (both lengthwise and widthwise)
Back of Specimen Ignition: Yes (both lengthwise and widthwise)
Flaming/Glowing Droplets: Yes (both lengthwise and widthwise)
Ignition Time: 00:20 (lengthwise), 00:23 (widthwise)
Specimen Material Falling Off in Separate Droplets: Yes (both lengthwise and widthwise)
Residual Length: Average 62.3 cm (lengthwise), Average 65.5 cm (widthwise)
Smoke Temperature: Maximum Average 154.7 °C (lengthwise), Maximum Average 151.8 °C (widthwise)
- Ignitability Test:
Flame Application Time: 15 seconds
Flaming Reaching the Gauge Mark Within 20 Seconds: No (both lengthwise and widthwise)
Afterflame Time: Ranging from 2 to 4 seconds
Maximum Flame Height: Ranging from 5 to 9 cm
Molten Dripping: No (both lengthwise and widthwise)
Test Report for M1 Inherent Flame Retardant Blackout Fabric
- Report Number: AJFS2405006006FF
- Sample Description: Inherent flame retardant blackout fabric, color white, composition 100% polyester.
- Test Requirements: According to NF P 92-507:2004 standard, the fire reaction of building interior fitting materials is classified.
- Test Results: The sample is classified as M1 level.
- Test Details:
- Electrical Burner Test (NF P 92-503:1995):
Hole Formation During Testing: Yes
Application Time: 20 seconds
Maximum Afterflame Time: 0 seconds
Flaming Molten Droplets: No
Non-flaming Molten Droplets: No
Flaming Debris: No
Non-flaming Debris: No
White-hot Spots with Propagation Effects: No
Maximum Destruction Length: Average 40 mm
Destroyed Width: 0 mm
- Flame Persistence Test (NF P 92-504:1995):
Ignition Time: 0 seconds
After-flame Time: Ranging from 0 to 30 seconds
Flaming Drops: No
Non-flaming Drops: No