Test Report Summary: NFPA701 Test for Flame Resistance
- Report Number: AJFS1704002052FF
- Sample Description: Inherent Flame Retardant Blackout Fabric
- Color: Black
- Composition: 100% Polyester
- Manufacturer: Shaoxing Begoodtex Co., Ltd
- Test Requested: NFPA 701:2015 Standard Methods for Flame Propagation of Textiles and Films, Test Method 1
- Conclusion: The tested sample meets the requirements of NFPA 701:2015, Test Method 1.
Test Details
- Sample Description: Fabric (Black)
- Area Density: Approx. 254 g/m²
- Sample Configuration: Single Layer
- Sample Size: 150mm x 400mm, 10 specimens, length parallel to material length
Conditioning and Cleaning
- Pre-Test Conditioning: Conditioned at 105℃ for at least 30 minutes
Test Results
Specimen No. | Mass Before Test (g) | Mass After Test (g) | Mass Loss (%) | After Flame Time (s) | Burning Time on Floor (s) |
---|---|---|---|---|---|
1 | 16.33 | 12.28 | 24.80 | 0 | 0 |
2 | 16.27 | 12.57 | 22.74 | 0 | 0 |
3 | 16.32 | 13.31 | 18.44 | 0 | 0 |
4 | 16.48 | 12.31 | 25.30 | 0 | 0 |
5 | 16.37 | 12.81 | 21.75 | 0 | 0 |
6 | 16.29 | 12.93 | 20.63 | 0 | 0 |
7 | 16.38 | 13.07 | 20.21 | 0 | 0 |
8 | 16.30 | 12.46 | 23.56 | 0 | 0 |
9 | 16.22 | 12.50 | 22.93 | 0 | 0 |
10 | 16.37 | 12.32 | 24.74 | 0 | 0 |
- Average Mass Loss: 22.51%
- Standard Deviation (SD): 2.24
- Mean + 3SD: 29.23
Observations
- Vigorousness of Burning: None
- Material Molten Dripping: Yes
- Odor Smoke: Yes
Criteria for Passing NFPA 701:2015 Test Method 1
- No specimen fragments or residues continued to burn on the floor for more than 2 seconds.
- The average weight loss was less than 40%.
- No individual specimen deviated more than 3 standard deviations from the mean weight loss.
- The sample passed all conditions, meeting NFPA 701:2015 standards.