Can’t Find What You Are Looking For? Find Out About Our Bespoke Design Solutions.
Inherent Flame Retardant Blackout Fabric Fire Retardant Curtain Fabric for Hotel
SKU: BG-ZG-321
- NFPA701,M1 EN13501-1,EN13773 CLASS 1,BS5867-2 TYPE C,DIN4102-B1,CANULC-S109-14,CA TITLE 19 section1237,UIC564-2,IMO
- 150/280/300cm
- 250/260/280/420gsm
- Flame retardant, Blackout, Anti-uv, GRS, Soundproof, Heat and Cold Protection
- 100% polyester
- Curtain
- NFPA701-balck-2017-5
Usually we provide A4 size samples, samples are free, you only need to pay the shipping cost, if you need more sample quantity, please contact us.
Test Report Summary: NFPA701 Test for Flame Resistance
- Report Number: AJFS1704002052FF
- Sample Description: Inherent Flame Retardant Blackout Fabric
- Color: Black
- Composition: 100% Polyester
- Manufacturer: Shaoxing Begoodtex Co., Ltd
- Test Requested: NFPA 701:2015 Standard Methods for Flame Propagation of Textiles and Films, Test Method 1
- Conclusion: The tested sample meets the requirements of NFPA 701:2015, Test Method 1.
Test Details
- Sample Description: Fabric (Black)
- Area Density: Approx. 254 g/m²
- Sample Configuration: Single Layer
- Sample Size: 150mm x 400mm, 10 specimens, length parallel to material length
Conditioning and Cleaning
- Pre-Test Conditioning: Conditioned at 105℃ for at least 30 minutes
Test Results
Specimen No. | Mass Before Test (g) | Mass After Test (g) | Mass Loss (%) | After Flame Time (s) | Burning Time on Floor (s) |
---|---|---|---|---|---|
1 | 16.33 | 12.28 | 24.80 | 0 | 0 |
2 | 16.27 | 12.57 | 22.74 | 0 | 0 |
3 | 16.32 | 13.31 | 18.44 | 0 | 0 |
4 | 16.48 | 12.31 | 25.30 | 0 | 0 |
5 | 16.37 | 12.81 | 21.75 | 0 | 0 |
6 | 16.29 | 12.93 | 20.63 | 0 | 0 |
7 | 16.38 | 13.07 | 20.21 | 0 | 0 |
8 | 16.30 | 12.46 | 23.56 | 0 | 0 |
9 | 16.22 | 12.50 | 22.93 | 0 | 0 |
10 | 16.37 | 12.32 | 24.74 | 0 | 0 |
- Average Mass Loss: 22.51%
- Standard Deviation (SD): 2.24
- Mean + 3SD: 29.23
Observations
- Vigorousness of Burning: None
- Material Molten Dripping: Yes
- Odor Smoke: Yes
Criteria for Passing NFPA 701:2015 Test Method 1
- No specimen fragments or residues continued to burn on the floor for more than 2 seconds.
- The average weight loss was less than 40%.
- No individual specimen deviated more than 3 standard deviations from the mean weight loss.
- The sample passed all conditions, meeting NFPA 701:2015 standards.
Reviews
You must be logged in to post a review.
Similar Items
There are no reviews yet.