Can't Find What You Are Looking For? Find Out About Our Bespoke Design Solutions.
Inherent Flame Retardant Blackout Fabric Woven Flame Resistant UV Proof Fabric
SKU: BG-ZG-301
- NFPA701,M1 EN13501-1,EN13773 CLASS 1,BS5867-2 TYPE C,DIN4102-B1,CANULC-S109-14,CA TITLE 19 section1237,UIC564-2,IMO
- 150/280/300cm
- 250/260/280/420gsm
- Flame retardant, Blackout, Anti-uv, GRS, Soundproof, Heat and Cold Protection
- 100% polyester
- Curtain
- NFPA701-2018-8
Usually we provide A4 size samples, samples are free, you only need to pay the shipping cost, if you need more sample quantity, please contact us.
Test Report Summary: NFPA701 Test for Flame Resistance
- Sample Description: 100% Polyester Inherent Fire Retardant Blackout Fabric
- Color: White
- Composition: 100% Polyester
- Test Requested: NFPA 701:2015 Standard Methods for Flame Propagation of Textiles and Films, Test Method 1
- Conclusion: The tested sample meets the requirements of NFPA 701:2015, Test Method 1.
Test Details
- Sample Description: Fabric (White)
- Area Density: Approx. 264 g/m²
- Sample Configuration: Single Layer
- Sample Size: 150mm x 400mm, with length parallel to material length
Conditioning and Cleaning
- Cleaning Procedure: None
- Pre-Test Preparation: Dried in an oven at 105℃ for 30 minutes.
Test Results
Specimen No. | Mass Before Test (g) | Mass After Test (g) | Mass Loss (%) | After Flame Time (s) | Burning Time on Floor (s) |
---|---|---|---|---|---|
1 | 16.50 | 14.13 | 14.36 | 0 | 0 |
2 | 16.64 | 14.23 | 14.48 | 0 | 0 |
3 | 16.56 | 14.58 | 11.96 | 0 | 0 |
4 | 16.71 | 13.87 | 17.00 | 0 | 0 |
5 | 16.59 | 14.20 | 14.41 | 0 | 0 |
6 | 16.72 | 14.22 | 14.95 | 0 | 0 |
7 | 16.66 | 14.50 | 12.97 | 0 | 0 |
8 | 16.57 | 14.09 | 14.97 | 0 | 0 |
9 | 16.63 | 14.27 | 14.19 | 0 | 0 |
10 | 16.59 | 14.08 | 15.13 | 0 | 0 |
- Average Mass Loss: 14.44%
- Standard Deviation (SD): 1.33
- Mean + 3SD: 18.43
Observations
- Vigorousness of Burning: None
- Material Molten Dripping: Yes
- Odor Smoke: Yes
Criteria for Passing NFPA 701:2015 Test Method 1
- No specimen fragments or residues continued to burn on the floor for more than 2 seconds.
- The average weight loss was less than 40%.
- No individual specimen deviated more than 3 standard deviations from the mean weight loss.
- The sample passed all conditions, meeting NFPA 701:2015 standards.